VRF Air Conditioning

 

MRV milestones & MRV IV line up

Powered By MHI Qingdao
MRV IV Line up

R&D Powered by MHI Qingdao and Haier

MRV IV produced in MHI Qingdao factory, which export the products to Japan and also global markets

Production In MHI Qingdao Factory

MRV milestones & MRV IV line up

MRV milestones & MRV IV line up

Combination Line-up

Max 3 modules combination 72HP, every 2HP one model.
Footprint of 72HP only 2.92m2, 50% size reduced

FULL DC INVERTER HIGH EFFICIENCY

Full DC Inverter technology
Key parts to support full DC inverter technology
High efficiency

Full DC Inverter Technology
Full New Outlook, Full DC Inverter Technology Key Parts
IPLV(c) up to 7.6, average IPLV(c) up to 6.9, low running cost
Higher energy efficiency than MRV IIIment with Google Fonts

EASY INSTALLATION

Largest capacity single module,smallest footprint
Long pipe length,high height drop
High outdoor ESP

Largest capacity single module in the industry: 24HP ,
Smallest footprint in the industry :0.97m2
Long pipe length, high height drop
82Pa ESP, Long air duct connecting available

COMFORT

Wide operation range
Low noise, night silent running
Optimal temperature control

Wide operation range, -23°C heating, 53°C cooling
Low noise and night silent running
Optimal Temperature Control

When a multiple number of indoor units are connected, an insufficient or excess amount of refrigerant may be
supplied to indoor units depending on the difference in length of the piping connection from outdoor units
Optimal refrigerant control uses the indoor coil temperature to detect the air conditioning status of each indoor
unit and control the capacity(refrigerant amounts) very precisely

HIGH RELIABILITY

Recycling operation
stage oil return
Oil temperature sensor
High Pressure sensor
Thunder Protection

Recycling operation
Recycling operation ,more long life of compressor

Oil Return

If the compressor operate at low frequency,oil return is only through the capillary.
If the discharge compressor operate at high frequency,oil return is through the capillary and magnetic valve.

Compressor double protection:

Base on the basic air discharge sensor ,MRV IV add the oil temperature sensor at the bottom of compressor

With the oil temperature sensor
Control the on/off of heater of compressor, preventing from the liquid shock of compressor
Control the on/off of heater of compressor, preventing
from the liquid shock of compressor
Judge if the liquid refrigerant enter into the compressor
Compressor oil sub heating protection.

•High pressure sensor for every compressor, back up operation so for the module with 2 compressors ,there are 2 high
pressure sensors and 1 low pressure sensors, total 3 sensors

Thunder protection

There are electricity discharge wire in the terminal block, to lead the
abnormal

voltage into the earth, then to prevent the thunder affect.

CLOUD SERVICE PLATFORM

Cloud Service

MRV IV-C

MRV IV-C