VRF Air Conditioning

MRV milestones & MRV IV line up
Powered By MHI Qingdao
MRV IV Line up
R&D Powered by MHI Qingdao and Haier
MRV IV produced in MHI Qingdao factory, which export the products to Japan and also global markets
Production In MHI Qingdao Factory
FULL DC INVERTER HIGH EFFICIENCY
Full DC Inverter technology
Key parts to support full DC inverter technology
High efficiency
Full DC Inverter Technology
Full New Outlook, Full DC Inverter Technology Key Parts
EASY INSTALLATION
Largest capacity single module,smallest footprint
Long pipe length,high height drop
High outdoor ESP
Largest capacity single module in the industry: 24HP ,
Smallest footprint in the industry :0.97m2
COMFORT
Wide operation range
Low noise, night silent running
Optimal temperature control
Wide operation range, -23°C heating, 53°C cooling
Low noise and night silent running
Optimal Temperature Control
When a multiple number of indoor units are connected, an insufficient or excess amount of refrigerant may be
supplied to indoor units depending on the difference in length of the piping connection from outdoor units
Optimal refrigerant control uses the indoor coil temperature to detect the air conditioning status of each indoor
unit and control the capacity(refrigerant amounts) very precisely
HIGH RELIABILITY
Recycling operation
stage oil return
Oil temperature sensor
High Pressure sensor
Thunder Protection
Recycling operation
Recycling operation ,more long life of compressor
Oil Return
If the compressor operate at low frequency,oil return is only through the capillary.
If the discharge compressor operate at high frequency,oil return is through the capillary and magnetic valve.
Compressor double protection:
Base on the basic air discharge sensor ,MRV IV add the oil temperature sensor at the bottom of compressor
With the oil temperature sensor
Control the on/off of heater of compressor, preventing from the liquid shock of compressor
Control the on/off of heater of compressor, preventing
from the liquid shock of compressor
Judge if the liquid refrigerant enter into the compressor
Compressor oil sub heating protection.
•High pressure sensor for every compressor, back up operation so for the module with 2 compressors ,there are 2 high
pressure sensors and 1 low pressure sensors, total 3 sensors
Thunder protection
There are electricity discharge wire in the terminal block, to lead the
abnormal
voltage into the earth, then to prevent the thunder affect.
CLOUD SERVICE PLATFORM
Cloud Service