Cassettes Air Conditioning

 

FEATURES

HEALTH

Premium air filtration for removal of smaller airborne dust particles, and other materials.

In cooling or dehumidification mode operation, the dust on the evaporator is removed with the condensate water, and after the cooling has shut down the fan will continue to operate to dry the evaporator.

ENERGY

Demand Response Enabling Device. It provides a method by which a power supply company limit the amount of power that a appliance will consume. The aim is to reduce peak demand to the power supply network at critical peak load times.

DC inverter A-PAM inverter 180°sine wave inverter technology will
reduce vibration at low compressor frequency , reduce noise and energy
at lower RPM’s when compared to a standard inverter system.

Latest technology DC motor adopted instead of AC motors. DC motor
require reduced power to operate versus a typical AC motor. Built-in
microprocessor allows for programmability and better airflow control,
lower vibration and lower noise levels at varying speeds.

On/Off control card can be managed by a simple on/off device such as a
hotel card system

TECHNOLOGY

Connection of more than one indoor unit so they can operate as a
group.

Connection to a accessory central control device to allow independent
operation of more than one device at a central location.

Connection possible to a Building Management System via a interface
accessory device.

Built in timer

Prevent unauthorised operation

Self diagnosis function. In the event of failure a error code will be
displayed.

CONVENIENCE

Inbuilt condensate pump to elevate condensate to allow for flexible
location of indoor unit.

Pipe connection inside cabinet for a smooth exterior

COMFORT

Built-in microprocessor automatically detects room temperature and determines operation mode either heating or cooling.

Control via with smart phone or tablet which can connect to the Internet

Outlet louvers can be independently controlled.

Branch outlet for connection to ducting

Wide angle airflow.

Adoption of DC fan motor permits 4 fan speed control by the
user.

Temperature requirement shift during sleep, as we remain
inactive. The system will adjust temperature and noise for a
more comfort during sleep.

Fresh air duct connection to allow fresh air to be ducted directly
into the unit, improving room oxygen levels.

Dry Mode concentrates on RH% humidity reduction and less
on temperature.

Microprocessor controlled motors change the direction of
outlet airflow, imitating nature.

RELIABILITY

Outdoor unit designed for heating operation down to – 20 °C

Outdoor Unit designed for cooling operation down to – 15 °C

The heat exchanger aluminium fin stock has a Hydrophilic
coating for its anti- corrosion properties and its low surface
tension, which enables water droplets to flow off the surface
better than standard Aluminium fin.

Designed for both 50 and 60Hz power supply.

Allows the system pressures to balance before attempting
start of the compressor, to prevent damage and excessive
power consumption.

Auto restart after power failure, in the event of a power outage.

Individual flap control

The four outlet louvers can be controlled individually by the
controller, providing maximum comfort throughout the room.

360° air supply

360° air supply without blind spots

Hidden LCD Display

Hidden LCD display design. Green display for cooling red display
for heating.

ABS Panel plastics

The 360°smart flow cassette panel is manufactured from high
grade ABS plastic designed to resist yellowing over time..

High lift drain pump

Pump can lift up to 1200mm.

Fresh Air Inlet

Pre-set fresh air inlet can introduce the outside fresh air into
the room, to improve the indoor air quality.

High Ceiling Mode (1)

Indoor unit can be installed 4.5 meters high.
(1)Wired controller YR-E17/YR-E16A required

Installer friendly

The electrical panel can be removed with one screw.

Moving eye intelligent panel

Model PB-9500MB: The panel has a eye that can detect
movement in the room.

Airflow direction

The airflow can be set to follow or avoid occupants, to
improve the comfort level.

CASSETTE MODELS

page112

CASSETTE MODELS

DRAWINGS

OUTDOOR UNITS

1UH071N1ERG 1UH090N1ERG 1UH105N1ERG

1UH125P1ERG 1UH125P1ERK 1UH140P1ERK

DRAWINGS

INDOOR UNITS

CASSETTE
ABH071H1ERG ABH090H1ERG ABH105H1ERG

ABH125K1ERG ABH140K1ERG

CONTROL SYSTEM

YR-HBS01

• On/Off. Mode. Fan speed. Temperature setting. Swing Individual
control
• Indoor Temp. & Humidity display
• Four grades of fan speed
• Individual blade control for cassette
• Follow/Avoid function

YR-E17

• On/Off, Mode, Fan speed, Temperature setting, Swing.
• Individual & Group control (Max 16 indoor units)
• Small, Simple and Smart design, 86*86*13.05mm
• Touch screen with back light
• Timer /Clock
• Individual blade control for Smart Power Cassette

YR-E16A

• On/Off, Mode, Fan speed, Temperature setting, Swing
• Individual & Group control (Max 16 indoor units)
• Large touch button
• Fahrenheit/ Celsius selectable; Sensitivity ±0.5°C
• Individual blade control for Smart Power Cassette
• Static pressure setting
• Error display in sequence of date

KZW-W002

• Internet remote control, Wi-Fi control
• Weekly timer

CENTRAL CONTROL SYSTEM

YCZ-G001

• Individual control, Group control & Central control (Max 32 indoor units)
• Large touch key
• Weekly timer.
• Unit name & Group name free setting. Four background available (mall,
hotel, office, home)
• Error display

YCZ-A004

• Individual control, Group control & Central control (Max 256 indoor
units)
• 7-inch TFT LCD touch screen with back light
• Schedule control
• Indoor units information edit
• When used in conjunction with MRV, One IGU05 is required for each
MRV system
• (Max. 32 sets)

HCM-05, HCM-05A

• Third party interface: BACnet IP
• Max. 250 indoor units can be controlled for HCM-05; and 500
indoor units for HCM-05(A) including 128 super match indoor units
maximum.
• When used with Max. 32 systems. Each system requires one IGU02.